Concept of The Various Aspects of The CT Tangent Delta Testing
CT tangent delta testing is a sort of diagnostic procedure that assesses the tangent delta, or dielectric loss factor, of a CT insulating system. A measure of the caliber and consistency of the insulation, tangent delta is the proportion of resistive loss to reactive loss in an insulation system.
Between the primary and secondary windings of the CT, the insulation system uses insulation materials like oil, paper, or synthetic materials to provide electrical insulation. The insulating system could deteriorate over time as a result of heat, moisture, pollutants, or aging, among other things. The windind resistance testing can offer important details regarding the health of the transformer or other electrical machine.
Due to this deterioration, the insulation may lose some of its dielectric strength, reducing CT accuracy, increasing mistakes, and perhaps posing safety risks. In CT tangent delta testing, the insulation system is subjected to a voltage, and the current flowing through the insulation is monitored at a particular frequency. A frequency close to the CT's operational frequency is used for the test to simulate real-world usage. The difference between the resistive and reactive losses is then used to compute the tangent delta. The quality of the insulation improves as the tangent delta value decreases.
To detect potential insulation issues before they lead to equipment failure or safety threats, CT tangent delta testing offers useful information about the state of the CT insulation system. For the maintenance and condition monitoring of CTs, it is a crucial diagnostic tool.
While commissioning new CTs, doing routine maintenance, or following a significant malfunction or failure, CT tangent delta testing is frequently carried out.
It is recommended that certified and experienced personnel carry out CT tangent delta testing using calibrated tools, as per the manufacturer's instructions and any relevant standards. Professionals should interpret the test results so they can examine, assess, and, if necessary, suggest the best course of corrective action.
A diagnostic test called winding resistance testing examines the DC resistance of the windings in a transformer or other electrical machine. The winding resistance test is carried out to check the reliability of the electrical connections, and the caliber of the insulation, and to look for any winding flaws.
The total resistance of the primary and secondary windings in a transformer is known as the winding resistance. The diameter of the wire, the length of the winding, and the number of turns all affect how resistant the windings are. To test the winding's resistance, a known DC must be passed through it, and the voltage drop across the winding must be recorded. The resistance of the coil is then determined using Ohm's law.
An issue with the electrical connections, such as loose or corroded connections, may be indicated by excessively high winding resistance. A winding insulation issue, such as cracks, vacancies, or other problems, may also be indicated by high winding resistance. The winding may become overheated and suffer damage if there is a short circuit between turns, which can be indicated by a winding resistance that is too low.
To find out if the winding resistance has changed over time, the winding resistance test is normally carried out when a new transformer is being commissioned or as part of routine maintenance. To determine the amount of the windings' damage following a defect or failure, the test is also carried out.
Conclusion
Windind resistance testing should be done by certified and experienced professionals using calibrated tools, as directed by the manufacturer, and following any applicable regulations. Professionals should interpret the test results since they have the knowledge and experience to assess, evaluate, and, if necessary, suggest suitable corrective steps.